Skip Navigation
Emerging Disease Issues in MichiganMichigan.gov, Official Website for the State of Michigan
Michigan.gov Home
close print view

Part 03: Removal of Brain Stem Via Foramen Magnum

OPTION 2 (PREFERRED): 

Removal of Brain Stem Via Foramen Magnum 
This procedure is relatively easy in elk compared to deer having a smaller foramen magnum. Still, even with the smallest of deer breeds - a little practice makes perfect and the technique becomes quite routine.

  tech preparing for removal of brain stem 

  1. Personal Protective Equipment (PPE) and Clothing not limited to safety goggles, disposable respirator mask and disposable gloves MUST be worn during sample collection.

  2. Tools needed are a small pair of scissors (curved best), pair of wide-tipped grasping forceps and an instrument of choice for brainstem removal.  This instrument may be a grapefruit knife or spoon, a modified small or mid-sized spoon, a jet stream of water or simply anything that ultimately gets the job done with a successful outcome.


    removal instruments

    The second instrument from the left is a modified, heavier gauge metal table spoon. It works well with elk/larger deer with bigger foramen magnum openings.


    additional instruments

    The second instrument from the left is a sharp-pointed, serrated grapefruit knife with the tip bent in an upward direction.  It works well with deer having smaller foramen magnum openings.


    detaching deer head
  3. CAREFULLY and SAFELY detach the head from the carcass at the atlanto-occipital joint where the skull meets the neck bones. The foramen magnum with spinal cord protruding out should be seen when done properly.

  4. Place the head on a flat, disinfectable, surface at a comfortable working height.
    Have the head upside down with nose pointing away from you.

  5. separate from spinal cord

    With forceps or tweezers, take hold of the end of the spinal cord.  Gently insert either special spoon or knife (grapefruit in this case) between the spinal cord and the tough sheath (dura mater) surrounding it to a depth of  2 - 2 ½ inches.

  6. cutting spinal cord

    Sweep the knife in a 360 degree arc around the top, sides and bottom of the spinal cord to cut the attachments being careful to stay close to the bone.

  7. cutting spinal cord

    Insert the knife/spoon (modified spoon in this case with elk being sampled) below the spinal cord and advance it forward 3-4 inches keeping it below the spinal cord. Tip the end of the knife/spoon upward making contact with the bone and gently pull the knife/spoon backward.

  8. removing spinal cord

    At the same time or alternating times, gently pull in backward motion with forceps on spinal cord while pulling back on spoon with tip pointed upward rubbing against inside skull to remove severed brainstem.

  9. good spinal cord sample

    A GOOD REPRESENTATIVE SAMPLE OF THE BRAINSTEM PORTION NEEDED FOR CWD TESTING.  It is very important that the juncture where the spinal cord and brain meet forming a "V" be submitted with the remainder of brainstem.

  10. spinal cord sample in container

    Immerse the entire brainstem in 10% NB formalin.  Make sure the tissues are "drowning" in the formalin.  Add more 10% NB formalin from an unused jar if you need more formalin. If the jar is not large enough (elk brains possibly) then use an appropriate larger, watertight unbreakable (plastic, etc.) jar, which can be sealed with tape.

  11. sample label    sample label

    Properly identify the sample by placing MDA-CWD on lid along with sex, age, owner's name and/or farm name, date collected, specimen tissue type and animal or sample identification number.

Download this document in PDF format

Related Content
 •  Part 01: Intro to Cervid CWD Sample Submission Protocol
 •  Part 01: Intro to Cervid CWD Sample Submission Protocol PDF

 PDF icon
 •  Part 02: Complete Head Submission
 •  Part 02: Complete Head Submission PDF

 PDF icon
 •  Part 01a: Step by Step Sample Collection from Cervids PDF icon
 •  Part 03: Removal of Brain Stem Via Foramen Magnum PDF

 PDF icon
 •  Part 04: Complete Brain Removal
 •  Part 04: Complete Brain Removal PDF

 PDF icon
 •  Part 05: Collecting Medial Retropharyngeal Lymph Nodes
 •  Part 05: Collecting Medial Retropharyngeal Lymph Nodes PDF

 PDF icon
 •  Part 06: Labeling Sample Containers & Animal ID
 •  Part 06: Labeling Sample Containers & Animal ID PDF

 PDF icon
 •  Part 07: Laboratory Submission Form
 •  Part 07: Laboratory Submission Form PDF

 PDF icon
 •  Part 08: Shipping Samples & Carcass Handling
 •  Part 08: Shipping Samples & Carcass Handling PDF

 PDF icon
 •  Part 09: Safety Precautions and Recommendations
 •  Part 09: Safety Precautions and Recommendations PDF

 PDF icon
 •  Part 10: Accreditation
 •  Part 10: Accreditation PDF PDF icon
QR code

Michigan.gov Home
PoliciesMichigan NewsMichigan.gov Survey

Copyright © 2014 State of Michigan