Volatilization Intrusion Guidance - Volume 3 provides information to EGLE staff and contractors for investigative approaches to Volatilization to Indoor Air Pathway (VIAP). This volume provides a generic approach for the investigation and evaluation of the VIAP for releases of chlorinated volatile organic compounds (CVOCs) and other non-petroleum compounds that are recalcitrant to aerobic biodegradation. This document is available as a technical reference to assist any party response activity for VIAP.
Please email Nick Swiger at SwigerN@Michigan.gov with any questions, comments, concerns, or technical challenges.
Executive Summary
The presence of a volatile hazardous substance associated with soil, groundwater, or nonaqueous phase liquid (NAPL) that may form vapors is called a vapor source. A vapor source, in sufficient concentrations, may pose an unacceptable risk to human health through the Volatilization to the Indoor Air Pathway (VIAP).
This volume provides a generic approach for the investigation and evaluation of the VIAP for releases of chlorinated volatile organic compounds (CVOCs) and other non-petroleum compounds that are recalcitrant to aerobic biodegradation. For aerobically degradable compounds such as petroleum hydrocarbons, Volume 4: Investigative approach for Petroleum VIAP should be consulted.
The potential routes of exposure associated with VIAP consists of:
- Vapor Intrusion: the volatilization and migration of volatile chemicals in the vapor phase from NAPL, contaminated soil, or groundwater into indoor air spaces of buildings. This occurs when vapors from these chemicals enter buildings primarily through openings such as cracks in the foundation and gaps around utility lines.
- Direct Volatilization: the process by which a source of vapors, either as NAPL or as a dissolved vapor source in groundwater, migrate into a building and directly volatilize into a building’s breathing space without migrating through the vadose zone resulting in a potential unacceptable exposure risk to human health.
The risk evaluation associated with the VIAP should only focus on those potential vapor sources that include contaminated groundwater at the surface (i.e., top) of the zone of saturation and areas where the volatile hazardous substance (i.e., contaminated soil and NAPL) is located above the saturation zone. If the contaminated groundwater plume or NAPL is below clean groundwater, there is no vapor source is present that can pose an unacceptable risk to the VIAP. For the VIAP, initial screening is conducted by the application of a lateral separation distance of 100 feet from the vapor source and/or strategic placement of soil gas samples above and around the contaminated soil and groundwater. However, where direct volatilization is the route of exposure or a vapor source has entered a conduit, which for the purposes of this document is any utility that can directly transport a vapor source and vapors to a building, indoor air sampling may also be needed to evaluate the potential risks.